AC/DC Current clamp
The 80I-110s is compatible with any Fluke ScopeMeter Test Tool, Power Harmonics Analyzer, Oscilloscope, Multimeter, or other voltage measurement device that has the following features: BNC input connectors or if using a meter convert the banana plugs to a BNC connector using the adapter PM9081/001.
- Current Range: 0.1 to 100A DC or 0.1 to 70A AC
- Basic Accuracy (DC to 1kHz):
100mV/A setting: 50mA to 10A +/- 3% of reading + 50mA
10mV/A setting: 50mA to 40A +/- 4% of reading + 50mA
40A to 80A +/- 12% of reading + 50mA
80 to 100A +/- 15% of reading
- Output Signal: 10A range: 100mV/A | 100A range: 10mV/A
- Bandwidth: 1Hz to 20kHz
- Working Voltage: 600V AC rms
- Maximum Conductor Size: 11.8 mm (.46 inch) diameter
- Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V
Specifications |
Nominal current range |
|
Continuous current range |
|
0.1 A - 10 A AC/DC |
|
1 A - 100 A AC/DC |
|
Maximum Non-Destructive Current |
|
Lowest measurable current |
|
Basic Accuracy |
|
3% + 50 mA (@ 10 A) |
|
(% reading + floorspec) |
|
Useable frequency |
|
Output level(s) |
|
Zero error adjustment |
|
Safety Specifications |
Safety |
|
CAT II, 600 V |
|
CAT III, 300 V |
|
Maximum voltage |
|
Mechanical & General Specifications |
Warranty |
|
Battery Life |
|
Maximum conductor diameter |
|
Output cable length |
|
BNC Adapter |
|