德国费希尔发布新款涂层测厚仪
此次发布的共有6款新型号,分别是:
DELTASCOPE® FMP30 磁性涂层测厚仪
DELTASCOPE® FMP10 磁性涂层测厚仪
DUALSCOPE® FMP40 磁性/非磁性双功能涂层测厚仪
DUALSCOPE® FMP20 磁性/非磁性双功能涂层测厚仪
ISOSCOPE® FMP30 非磁性(涡流)涂层测厚仪
ISOSCOPE® FMP10 非磁性(涡流)涂层测厚仪
上海君达现货供应德国费希尔涂层测厚仪,咨询电话:
上海:021-60496867 联系人:李先生,张小姐
北京:010-51269618 联系人:路先生
下面为此系列新的涂层测厚仪的英文介绍:
DELTASCOPE® FMP10 User for the measurement of non-ferromagnetic metal coatings, e.g., chrome, copper, zinc, as well as paint,
lacquer, enamel or plastic coatings on steel and iron.
ISOSCOPE® FMP10
User for the measurement of paint, lacquer or plastic coatings on non-ferromagnetic metal substrate materials;used for anodic coatings on aluminium as well as electrically conducting coatings on non conducting carrier
materials.
DUALSCOPE® FMP20
Due to automatic substrate material recognition and the combination of both measurement methods, this universal instrument is capable of measuring numerous coatings both on iron/steel and on non-ferromagnetic metals and on non-conducting carrier materials.
Characteristic features of the FMP10-20 series.
• For all magnetic induction and eddy current probes
• Automatic probe recognition
• Automatic base material recognition (FMP 20)
• User-friendly instrument operation
• USB port for data transfer to a PC
• Large, display rich in contrast with 240x160 pixels
• Ready to make measurements right after power-up
• Automatic measurement acquisition upon probe placement
• Memory for up to 1000 readings
• Audible signal at measurement acquisition
• Statistical display of common characteristic values such as mean value, standard deviation, min, max,range
• Easy adaptation to the shape of the specimen through a normalization by means of the ZERO key
• For strong differences in shape, additional corrective calibration using one or two calibration foils
• Master calibration for exact characteristics settings in case of extreme material and geometric properties
• Capability of storing the master calibration in the connected probe
• Units of measurement can be switched between μm and mils
• Adjustable instrument switch-off or continuous operation
• Various status displays (e.g., warning message when battery voltage drops)
• Lockable keyboard/restricted operating mode
• Mechanical sliders to cover keys not required for the measurement operation
• Various language settings
The new FMP30-40 series is even more versatile than the standard models FMP10-20. These instruments integrate additional features such as more memory for numerous applications as well as extensive statistical and graphical evaluations. Tolerance limits can be entered into the calibratable applications and the production process can be analyzed statistically. The default mode
can be switched to matrix mode for connected multipoint measurements. These are only a few of the many features described below.
Depending on your measuring application, you can make precise coating thickness measurements according to the magnetic induction method (DELTASCOPE® FMP30),the eddy current method (ISOSCOPE® FMP30) or according to both methods combined in one instrument
(DUALSCOPE® FMP40). You will be able to measure most standard or special applications with a wide assortment of Fischer plug-in type probes.
DELTASCOPE® FMP30
Used for the measurement of non-ferromagnetic metal coatings, e.g., chrome, copper, zinc, as well as paint,lacquer, enamel or plastic coatings on steel and iron.
ISOSCOPE® FMP30
Used for the measurement of paint, lacquer or plastic coatings on non-ferromagnetic metal substrate materials;used for anodic coatings on aluminium as well as electrically conducting coatings on non-conducting carrier materials.
FMP30-40 Series
Coating Thickness Measuring Instruments.
DUALSCOPE® FMP40
Due to automatic substrate material recognition and the combination of both measurement methods, this universal instrument is capable of measuring numerous coatings both on iron/steel, on non-ferromagneticmetals, and on non-conducting carrier materials.
Characteristic Features of the FMP30-40 Series:
(features additional to those of the FMP10-20 series)
• Automatic base material recognition (FMP40).
• Memory for up to 20,000 readings
• Up to 100 calibratable applications
• Capability of allocating readings into up to 4,000 blocks
• Date and time stamp for blocks
• Statistics display of common characteristic values in the block and fi nal results. Output of characteristic variance-analytical values
• Graphical measurement display as a histogram with a Gaussian plot
• Capability of entering process tolerance limits and computation of the associated process capability indices cp and cpk
• Audible and visual warning when tolerance limits are exceeded
• Free-running display with additional presentation of the reading as an analog bar between the tolerance limits
• External key-triggered measurement acquisition, e.g.,in hollow cylinders with small diameters
• Option to calibrate through an unknown coating (with magnetic induction method only)
• Capability to enable matrix measurement mode for connected multi-point measurements
• Capability of averaging measurement data: Only the mean value of several readings will be stored
• Measurement acquisition through area measurement possible:Only the single readings until probe lift-off are captured and averaged
• Capability to measure continuously with the probe placed on the specimen
• Outlier rejection for the automatic elimination of erroneous measurements
• Correction of any stored reading
• Application linking mode: Ability for common normalization/calibration of applications
• Designations for applications through the optional PC program MP-Name
• USB port to a printer
• Battery and line power operation
DUALSCOPE® FMP40 –With small parts
ISOSCOPE® FMP30 –Light alloy rim
DELTASCOPE® FMP30 –Truck brake disc